TYPICAL WIRING
AND CONFIGURATION 1F95-0671
TYPICAL WIRING DIAGRAMS
Single Stage
3-wire
Zone Valve
application
Blower/Circulator
Fan Energized
Opens
Valve
(4)
Constant
24 Volt
(Com-
mon)
24 Volt
(Hot)
Cool
System
6
Y
W
C
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt
(Hot)
Heat
(5)
RH
G
Jumper
Closes
Valve
(6)
3-Wire (SPDT) Heat Only Zone Valve Wiring
Thermostat must be in Heat, Cool or Auto. Press RUN SCHEDULE and then press hold the Menu button for at least 5 sec-
onds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press
or to
change a menu item options.
CONFIGURATION MENU
Menu
Ref. HP SS
Press
Button
Displayed
Factory (Default)
Press or
to select from
listed options COMMENTS
1 1 1 MENU (MS 2) HP 1, HP 2, SS 1 Selects Multi-Stage (MS 2 No Heat Pump),
Heat Pump 1 (HP 1, 1 compressor),
Heat Pump 2 (HP 2, 2 compressor or 2
speed compressor), or Single Stage (SS 1)
2 2 2 MENU (GAS) for SS or MS
(ELE) for HP
ELE GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
3 3 3 MENU (3) CS 0, 1, 2, 4, 5, 6 Selects Cool Savings
Value 1 (low) to 6 (high),
Value 0 disables feature
4 4 4 MENU (On) E OFF Selects Energy Management Recovery (EMR)
On or OFF.
5 5 MENU (ME) CR Heat SL, FA Selects Adjustable Anticipation, cycle rate, Heat
(This item only appears when MS 2 or SS 1 is selected above)
6 5 MENU CR Heat Pump
(ME)
SL, FA Selects Adjustable Compressor Anticipation
(Heat Pump) This item only appears when
HP 1, HP 2 is selected above
7 6 6 MENU (ME) CR Cool
or
(FA) CR AU
SL, FA
SL
Selects Adjustable Anticipation, cycle rate, cool (when MS 2 or
SS 1 is selected above.) or
Selects the cycle rate for Auxiliary stage (when HP 1 or HP 2 is
selected above)
8 7 7 MENU (OFF) CL CL On Compressor Lockout Time
9 8 8 MENU Em Heat, Auto
Cool Off
or
Heat, Auto, Cool Off
Heat Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon
Cool Off, Auto Off
System Mode Configuration
with Automatic Changeover capability
10 9 9 MENU (On) dL dL OFF Selects Display Light On or OFF
11 10 10 MENU 0
(current temperature)
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
12 11 11 MENU °F °C Selects Fahrenheit/Celsius Temperature Display
INSTALLER/CONFIGURATION MENU