OPERATION GUIDE
7 Day Multi-stage/Heat Pump
Electronic Digital Thermostat
1F94W-71
WHITE-RODGERS
Operator: Save this booklet for future use!
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - 1F94W-71

OPERATION GUIDE7 Day Multi-stage/Heat PumpElectronic Digital Thermostat1F94W-71WHITE-RODGERSOperator: Save this booklet for future use!

Strany 2

10The Thermostat Buttons7Sets the system mode (HEATing, OFF,COOLing, or AUTOmatic changeover).8Selects fan operation (see #5, above).9Runs display for

Strany 3 - In This Guide . .

1110 11 12 13 14 1516 17189785 DAY FANEMER. PUMPAUX.MALF.TIMEFWDSYSTEMHEAT/EMER/OFF/COOL/AUTOSETCLOCKVIEWPRGMHOLDCOPYTIMEBACKFANON-AUTOADVDAYVIEWTEMPR

Strany 4

12OPERATING FEATURESNow that you are familiar with the thermostatdisplay and buttons, read the following informa-tion to learn about the many features

Strany 5 - OPERATING YOUR THERMOSTAT

13Automatic ChangeoverSwitch #1 set at installation (DO NOT CHANGE)Switch #2 set at installation (DO NOT CHANGE)Switch #3 (see TOTAL KEYPAD LOCKOUT)S

Strany 6 - PARTS OF THE THERMOSTAT

14• TWO HOUR TEMPERATURE OVER-RIDE — Press or until the displayshows the temperature you want. The ther-mostat will override current programmingan

Strany 7

15To adjust heat anticipation, press SETCLOCK andADVDAY at the same time. The display willshow HEAT 18 (this is the factory prepro-grammed heating ant

Strany 8

16• AUDIO PROMPTING — Each time youpress a button, the thermostat will beep (thisfeature works only when the thermostat isattached to the wall and 24

Strany 9

17Total Keypad LockoutSwitch #1 set at installation (DO NOT CHANGE)Switch #2 set at installation (DO NOT CHANGE)Switch #3 ONSwitch #4 (see AUTOMATIC

Strany 10

18PROGRAMMING YOUR THERMOSTATNow you are ready to program your thermostat.This section will help you plan your thermostat’sprogram to meet your needs.

Strany 11 - AUX.MALF

193a. What time do the building occupants reacha minimum activity level (limited personnelin building)?b. What temperature should the building be atth

Strany 12 - OPERATING FEATURES

2Please read this manual thoroughly before operating or programming your thermostat. If you havequestions, you may write to our Technical Service Depa

Strany 13 - Switch #4 ON

20TemperatureDesignationFactoryPreprogrammedTemperatureYourSelectedTemperatureHEAT AHEAT BHEAT CHEAT DCOOL ACOOL BCOOL CCOOL D70°F64°F------78°F82°F--

Strany 14 - °F, repeat the process

21NOTE79787776757473COOLING TEMPERATURESHEATING TEMPERATURESDEAD BAND 1°FTo operate properly in the AUTO mode, theremust be a minimum 1°F separation b

Strany 15

22Period 1 Period 2 Period 3 Period 4TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp.MondayTuesdayWednesday

Strany 16 - HEAT/EMER/OFF/

23Period 1 Period 2 Period 3 Period 4TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp. TimeHeatTemp.CoolTemp.MondayTuesdayWednesday

Strany 17 - Switch #3 ON

24ENTERING YOUR PROGRAMFollow these steps to enter the heating/coolingprogram you have selected.We recommend that you remove the thermostatfrom the wa

Strany 18 - PROGRAMMING YOUR THERMOSTAT

255. Press SETCLOCK once. The display will show theday of the week as an abbreviation (MO forMonday, TU for Tuesday, etc.).6. Press and hold either TI

Strany 19

264. Press VIEWTEMP once. The letter A will change tothe letter B, representing HEAT B.5. Press either or to change thetemperature to your selecte

Strany 20

27EXAMPLE: This display window shows that for Monday’sheating/cooling period 1, the start time is5:00 AM, and 70° is the programmed tem-perature (this

Strany 21 - °F separation between

28NOTEThe thermostat has a built-in COPY feature.This feature automatically copies theheating and cooling programs you se-lect for Monday into Tuesday

Strany 22 - Heating/Cooling Schedule Plan

29Program Cooling TemperaturesIf outside temperature is below 50°F, werecommend that you remove the thermo-stat from the wall before proceeding withth

Strany 23

3Operator: Save thisbooklet for future use!Program Heating/Cooling Timesand Heating TemperaturesProgram Cooling TemperaturesUsing the HOLD/COPY Button

Strany 24

306. Use the HOLDCOPY button, or press ADVDAY tochoose other days to program. Remember,once you enter Monday’s program,Monday’s program is automatical

Strany 25

31step 2 you selected to copy Wednesday’sprogram, when you press HOLDCOPY, COPY 3will appear in the display (as shown below).EXAMPLE: 4. Press ADVDAY

Strany 26

32NOTEto the programming instructions to correctthe error.6. Press RUNPRGM.7. Press SYSTEMHEAT/EMER/OFF/COOL/AUTO until COOL is displayed.8. Repeat st

Strany 27

33QUESTIONS AND ANSWERS1. How can I permanently change a part ofmy program?Press VIEWPRGM until you reach the time/tem-perature schedule you want. The

Strany 28

34programming at this point, press RUNPRGM tostart the normal program function. See PRO-GRAMMING YOUR THERMOSTAT.4. What happens if the electricity go

Strany 29

35To correct this, remove the thermostat fromthe wall and remove the battery for at leasttwo minutes. After reinstalling the battery,the thermostat wi

Strany 30

368. Why doesn’t the display light come onwhen I press a button? Why don’t I heara beep when I press a button?The display light and audio prompting(be

Strany 31

37If the outside temperature is below 50°F,DO NOT use the button to move thetemperature below the setpoint tempera-ture. Property damage may result

Strany 32

3812. Why does the blower fan keep runningafter the system has turned off?The blower delay feature is operating. Thisenergy saving feature continues t

Strany 33 - QUESTIONS AND ANSWERS

3915. I live in an area where daylight savingstime is observed. How do I change thethermostat clock twice a year withoutaffecting thermostat programmi

Strany 34

4• Computed Energy Management Recovery(EMR)• Automatic changeover (operator-selectable)• Separate setback programming for 7 inde-pendent days• Simulta

Strany 35

RPart No. 37-5525A9529If you need further information on programming or operation, you may writeto our Technical Service Department at the address sho

Strany 36

5OPERATING YOUR THERMOSTATThe subbase is attached to the wall, but you canremove the thermostat body for easy program-ming. To remove the thermostat b

Strany 37

6PARTS OF THE THERMOSTATThe Back of The Thermostat BodyTurn the thermostat body over. On the back arethe 9 volt Energizer® alkaline battery and theopt

Strany 38

7Use SYSTEMHEAT/EMER/OFF/COOL/AUTO to turn thermostat OFF be-fore removing thermostat from the wallto replace the battery.2. You may adjust the option

Strany 39

84When VIEWTEMP is pressed, A is displayed whenthe setpoint temperature displayed (at thefar right) is the 1st programmed heating orcooling temperatur