1F80-240
(for HEATING ONLY systems)
Programmable Electronic Digital Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Heat program storage
Backlit display
Temperature override until next program period
Manual program override (HOLD temperature)
Temporary HOLD
°F/°C convertibility
Temperature range 45° to 90°F
RH, W, and G terminals
Battery powered
2 “AA” Energizer
®
alkaline batteries included
Operator: Save these instructions for future use!
Your new White-Rodgers 5-Day/1-Day/1-Day Digital Thermo-
stat uses the technology of a solid-state microcomputer to
provide precise time/temperature control. This thermostat offers
you the flexibility to design a heating program that fits your needs.
Features:
Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun) pro-
gramming with four separate time/temperature periods per day
Preprogrammed temperature control
LCD continuously displays set point, and alternately dis-
plays time and room temperature
PRECAUTIONS
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
! CAUTION
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
! WARNING
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
APPLICATIONS
For use with:
Standard heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems (no auxiliary heat)
Millivolt systems
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
Heat pump systems
Printed in U.S.A.
PART NO. 37-6325B
0148
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - 1F80-240

1F80-240(for HEATING ONLY systems)Programmable Electronic Digital ThermostatINSTALLATION ANDOPERATION INSTRUCTIONSFAILURE TO READ AND FOLLOW ALL INSTR

Strany 2 - INSTALLATION

2MountingholesMountingholesElectric/GasswitchScrew anchorsINSTALLATIONREMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installa

Strany 3 - Heating System

3Heating System1. Move SYSTEM switch to HEAT position. If the heatingsystem has a standing pilot, be sure to light it.2. Press to adjust thermostat

Strany 4 - OPERATION

4Before you begin programming your thermostat, you should befamiliar with its features and with the display and the locationand operation of the therm

Strany 5 - PROGRAMMING YOUR THERMOSTAT

51Step Press Button(s) Displayed (Factory Default) Press or to select: COMMENTSHOLD(0:00)0 to 8 hrs (in 15 minute increme

Strany 6 - CHECK YOUR PROGRAMMING

6Enter Heating Program1. Move the SYSTEM switch to HEAT.2. Press PRGM once. “MO TU WE TH FR” (indicating weekdayprogram) will appear in the display. A

Strany 7 - TROUBLESHOOTING

7Symptom Possible Cause Corrective ActionNo Heat/No Fan 1. Blown fuse or tripped circuit breaker. Replace fuse or reset breaker.(common problems) 2. F

Strany 8